Hiring for high-voltage and grid work: the questions to resolve first

Safety rules, competence, authorisation, NERS and site access: the questions employers should answer before recruiting for high-voltage and grid roles.

Magpie Renewables · Sources checked 12 October 2026 · Updated 18 November 2026

For employers hiring HV and grid roles

HV hiring goes wrong when a good candidate is offered a role before anyone has decided whose safety rules they will work under, or who will authorise them. This guide sets out nine questions to answer first, and who is responsible for each.

Scope. This guide covers recruitment for work on electricity networks in Great Britain. It draws on published documents from network operators and scheme bodies, checked on 12 October 2026. It is general recruitment guidance, not safety or legal advice. Your own safety rules, and those of the network operator, always take precedence.

1.Which network will the person work on?

The answer shapes everything else.

  • Transmission (England and Wales): above 132kV, up to 400kV, owned by National Grid Electricity Transmission.
  • Transmission (Scotland): 132kV, 275kV and 400kV, owned by SP Transmission and SSEN Transmission.
  • Distribution: 132kV and below in England and Wales, and below 132kV in Scotland.
  • Private networks: the substations and cabling a site owner operates, such as those on a solar or storage site.

2.Whose safety rules apply?

The person could work under:

  • your own safety rules
  • a distribution network operator’s
  • a transmission owner’s
  • a site owner’s

This decides who assesses and authorises them, and how. National Grid’s appointment document, for example, requires other employers to make sure their staff are assessed and authorised to National Grid’s own Safety Rules.

3.What work, at what voltage, on what equipment?

Write this down before you advertise. “HV engineer” can mean design, construction, jointing, protection and control, commissioning or operations, at voltages from 11kV to 400kV. Candidates and recruiters can only match what has been specified.

4.What level of responsibility does the role need?

Organisations use different levels of authority. National Grid’s appointment document, for example, uses these levels:

  • Person
  • Competent Person
  • Authorised Person
  • Senior Authorised Person (separate HV, LV and mechanical categories)
  • Control Persons

Your own rules may use different names. Agree the level the role needs, and whether the person is expected to reach it on arrival or after a period of supervised work.

5.How will you judge competence?

Under regulation 16 of the Electricity at Work Regulations 1989, no one may do work that needs technical knowledge or experience to prevent danger (or, where appropriate, injury), unless they have that knowledge or experience, or are suitably supervised.

Deciding whether a person is competent for your work is the employer’s responsibility. A recruiter can gather and check evidence, but cannot make that judgement for you.

6.Who will authorise the person, and how long will it take?

Authorisation is granted under a specific set of safety rules, for a defined scope and a limited period. It does not move automatically from one employer or network to another. Published examples:

SSEN DistributionAssesses candidates with theory and practical tests, followed by an interview. Requires re-training and re-assessment at least every four years. Staff authorised by another UK operator can follow a dedicated assessment route.

National Grid Electricity TransmissionRequires formal assessment before appointing a Senior Authorised Person.

Electricity North WestAuthorises independent connection providers’ staff itself for HV and EHV jointing, overhead line and substation work, with a written scope.

Ask whoever authorises your staff how long it usually takes. Build that into the start date. Don’t assume a candidate can act as an Authorised Person on day one.

7.Does the work involve contestable connections?

If you’re an independent connection provider, your NERS accreditation defines which contestable work your company can carry out. NERS, run by LRQA, accredits organisations, not individuals.

Individuals working for an accredited company may still need authorisation from the network operator. So check that the role sits within your accredited scope.

8.Which cards and training are needed for site access?

Site cards and HV competence are different things:

  • EUSR SHEA Power: a health, safety and environmental awareness registration for power-industry sites. It is valid for three years. It shows safety awareness training, not technical competence.
  • ECS cards: record identity, occupation and qualifications. They are not authorisations.

List the cards the site requires separately from the competence the role requires.

9.What evidence will you ask candidates for?

For each previous authorisation, ask for:

  • the voltage
  • the equipment
  • whose safety rules it was issued under
  • the level
  • the date it was last assessed or renewed

Also ask for training records, relevant qualifications, and references from the person who authorised them, where possible.

Where a role connects new generation or storage to a distribution network, remember that the installer carries out the commissioning tests and the network operator may witness them. Plan hiring for those roles around connection milestones.

10.Who does what

CheckWho is responsible

Recruitment screening against your briefThe recruiter

Competence assessment for your workThe employer

Authorisation under the applicable safety rulesThe organisation whose safety rules apply

Contestable work within accredited scopeThe accredited company (NERS)

Site access cardsThe candidate holds them; the site sets the requirement